1020
UPRIGHT PRECISION MANOMETERS
 
 
 
 











For accurate measurement of:

  • Pressure
  • Vacuum
  • Differential Pressure

Range from 5mbar to 3500mbar

Tough, clear acrylic block

No parallax error

Scale adjustable for zero

Check valve to help prevent fluid loss

Static Pressure Ratings

  • Standard 7 bar
  • High Pressure 35 bar
  • Very High Pressure 70 bar
A comprehensive range of upright single column manometers manufactured from clear, stable and tough acrylic block. Precision machined reservoirs and indicating columns ensure high accuracy. All manometers have overpressure chambers and check valves to inhibit fluid loss. Surface mounting and portable versions have trap tubes which allows the instrument to be inverted without spillage of the indicating fluid.
Zeroing is easy using the sliding scale. Direct reading scales take into account changes in reservoir fluid level without the need for further adjustment. All instruments are suitable for the measurement of pressure, vacuum or differential pressure of air or gas. To measure liquid pressures, integral vent valves are incorporated
Surface mounting and portable manometers have side connections, panel manometers have rear connections.
In addition to the standard instruments listed overleaf, we produce special units to solve specific problems. For manometers used in conjunction with D.P devices, direct reading flow scales can be supplied. A range of accessories including magnifying cursors, valve manifolds, stands, mounting boards and carrying cases are available.
Traceable certification to national standards via NAMAS calibrated master manometers can be supplied.

 

 

 

 

 

 

 

 

 

RANGES

Filling
RED OIL S.G.0.8.
BLUE WATER S.G.1.0
INERT S.G.1.88
Scale Units
Ins. w.g.
Cm w.g.
Millibars
Ins. wg.
Cm wg.
Millibars
Ins. wg.
Cm wg.
Millibars
Resolution
(20ths)
(mm)
(0.2)
(20ths)
(mm)
(0.2)
(l0ths)
(0.2)
(0.2)
Model
                   
A 0-2 0-5 0-5 0-21/2 0-6.5 0-6 A/M 0-41/2 0-11 0-10
B 0-41/2 0-11.5 0-11 0-5 0-14 0-12 B/M 0-10 0-25 0-25
C 0-8 0-20 0-20 0-10 0-25 0-25 C/M 0-19 0-8 0-48
D 0-12 0-30 0-30 0-15 0-38 0-38 D/M 0-28 0-2 0-70
D2  0-16      0-40 0-40 0-20 0-54 0-52 D2/M 0-40 0-102 0-100
E 0-24 0-60 0-60 0-30 0-76 0-76 E/M 0-56 0-142 0-140
F 0-32 0-80 0-80 0-40 0-100 0-100 F/M 0-75 0-190 0-190
G 0-48 0-120 0-120 0-60 0-150 0-150 G/M 0-112 0-284 0-284
H 0-58 0-150 0-145 0-74 0-185 0-180 H/M 0-140 0-350 0-340
J 0-80 0-210 0-205 0-100 0-260 0-255 J/M 0-190 0-480 0-440

Filling
MERCURY
DIMENSIONS mm
Scale Units
Ins. Hg.
Ins. wg.
Iblin2
Cm. Hg.
Millibars
Kpa
(Approximate)
Resolution
(20ths)
(ins)
(20ths)
(mm)
(2mbar)
(0.2)
 
Height
Depth
Model
             
P
HP&VHP    
 A/M 0-21/2 0-35 0-1.2 0-6.5 0-80 0-8
A(M)
156
160
STD
25 nom.
 B/M 0-51/2 0-75 0-2.6 0-14 0-180 0-18
B(M)
239
243
 HP
45 nom.
 C/M 0-10 0-135 0-5 0-25 0-350 0-35
C(M)
380
384
VHP
60 nom.
 D/M 0-15 0-200 0-7.5 0-38 0-500 0-50
D(M)
527
531
   
D2/M 0-20 0-280 0-10 0-54 0-700 0-70
D2(M)
702
706
   
E/M 0-30 0-400 0-15 0-76 0-1000 0-100
E(M)
976
980
Width
F/M 0-40 0-550 0-20 0-100 0-1350 0-135
F(M)
1273
1277
   
G/M 0-60 0-800 0-30 0-150 0-2050 0-205
G(M))
1912
1916
STD
55
H/M 0-74 0-1000 0-36 0-185 0-2530 0-253
H(M)
2150
2154
HP
67
J/M 0-100  0-1400  0-50 0-260 0-3500 0-350
J(M)
2913
2917
VHP
90

 

 

 

 

 

 

 

 

 

 

GENERAL INFORMATION

To order please state:

LIQUID pressure and differentials are measured by versions M/WF with integral vent valves to ensure an interface between the indicating liquid (mercury or S.G.1.88) and the liquid medium. Special scales give true readings taking into account the weight of medium on top of the indicating liquid. This reduces the scale range of mercury filled manometers by 0.93 and S.G. 1.88 by half approximately. For specially designed water flow gauges see Data Sheets 5000 and 6010.

Model

Version


Scale

Fluid

Connectors

Water Flow

Static
Pressure
Rating


Add accessories

 A(M)-J(M) 

P (surfacel/portable)
R (panel)

as range table or special

see range table

standard or to order

WF if required

Std 
HP
VHP


or extras as required

MANOMETERS are fitted as standard with nozzles for 6mm (1/4") bore flexible tubing.
CONNECTORS TO ORDER   Nozzle for 5mm or 8mm bore flexible tubing. Compression in plastic, brass or stainless steel for 5mm, 6mm or 8mm old rigid or semi-flexible tube.
HIGH PRESSURE TYPES HP are tested to 50 bar fitted as standard with metal compression connectors for 6mm O.D. tube. Isolating/equalising valve manifold is strongly recommended.
VERY HIGH PRESSURE TYPES VHP tested to 100 bar Normally supplied as assembly with stainless steel valve manifold.
INDICATING LIQUIDS
  • RED OIL free flowing paraffin based non-freezing, usable -5° to 40°C.
  • BLUE WATER distilled with additives to improve flow.
  • INERT S.G. 1.88 very free flowing but large change in density with temperature. Usable -20° to 40°C.
  • MERCURY triple distilled. Instruments have microporous discs and (gas pressure versions) filter discs to prevent spillage, reduce surge and virtually eliminate the escape of mercury.
SCALES in other units are available to special order

REVERSIBLE SCALES obtained by additional scale in side scale slot.

ACCESSORIES include magnifying cursor valves, valve manifolds, stands, backing boards and carrying cases.
website
design by:
Poddymeter Limited
Unit 2, Park Works, Borough Road, Kingston upon Thames, Surrey KT2 6BD, United Kingdom
Tel: 020 8546 9311 Fax: 020 8547 2325 www.poddymeter.co.uk E-MAIL:
Last Updated:
15-sep-05

Copyright © 2005 PODDYMETER LTD